Influence of upper layer properties on the ground temperature distribution


Creative Commons License

Yilmaz T., Özbek A., Yilmaz A., Büyükalaca O.

ISI BILIMI VE TEKNIGI DERGISI/ JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, cilt.29, ss.43-51, 2009 (SCI-Expanded) identifier

Özet

Ground temperature distribution is crucially important for ground source heat pump applications. Ground

can be composed of one or multi-layers. In this study, one and multi-layer ground temperatures were calculated

numerically considering the climatic conditions of Adana-Turkey. The accuracy of the results obtained from

numerical method was controlled using the ones analytically obtained for exactly the same simplifying assumptions.

It was shown that the simplifying assumptions for analytical calculations were not realistic. In the numerical

calculations, daily values of solar energy, relative humidity, wind velocity and ambient temperature were used for

yearly calculations of ground temperature distribution. Variation of ground surface properties with the months in a

year has significant effects upon temperature distribution. The depths for maximum and minimum temperatures in the

ground were very different in case of multi-layered grounds existing naturally or built artificially. Above mentioned

effects can be used to control ground temperature distributions in winter and summer.

Keywords: Ground temperature distribution; Ground surface properties; Multi-layer ground; Maximum-minimum

temperature; Ground temperature control.