NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, cilt.248, sa.1, ss.133-141, 2006 (SCI-Expanded)
The additive dose (AD), T-m(E-a)-T-stop, repeated initial rise (RIR), peak shape (PS) and computerized glow curve deconvolution (CGCD) methods were used to analyze the thermoluminescence (TL) glow peaks in natural zircon after P-irradiation between the dose level 0.015 Gy and approximate to 10 kGy. The CGCD and E-a-T-stop methods indicate that the glow curve of this material is the superposition of at least seven glow peaks, which were referred to as P1-P7, in the temperature range between room temperature (RT) and 400 degrees C. The dose responses and fading process of individual TL peaks of this material were also examined. The dose response behaviors of all peaks are different from each other and they are saturated at different dose levels. Peaks 1 and 2 completely disappeared after 1 month storage in the dark room at RT. On the other hand, the intensity of peaks 3 + 4 was approximately reduced to 80% of its original value whereas the other peaks (P5-P7) were not sufficiently affected during this period. (c) 2006 Elsevier B.V. All rights reserved.