Effects of food-simulating liquids on the mechanical properties of a silorane-based dental composite


Creative Commons License

Yesilyurt C., Yoldas O., ALTINTAŞ S. H., Kusgoz A.

DENTAL MATERIALS JOURNAL, cilt.28, sa.3, ss.362-367, 2009 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 28 Sayı: 3
  • Basım Tarihi: 2009
  • Doi Numarası: 10.4012/dmj.28.362
  • Dergi Adı: DENTAL MATERIALS JOURNAL
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.362-367
  • Çukurova Üniversitesi Adresli: Evet

Özet

The purpose of this study was to investigate the effects of food-simulating liquids (FSL) on the hardness and flexural strength (FS) of a new silorane-based composite and to compare it with methacrylate-based composites (MBCs). Four restorative materials (Filtek Silorane, P60, Z250, and Supreme XT) were used. Specimens for the FS and hardness measurements were fabricated in customized molds. Immediately after polymerization, the materials were stored in the following dietary simulating solvents at 37 degrees C for 1 week: distilled water, 0.02 N citric acid, heptane, and 75%, aqueous ethanol solution. After conditioning, the FS and hardness values were measured. Data were Subjected to ANOVA/Scheffes test at a significance level of 0.05, The hardness and FS of Filtek Silorane were not significantly affected by FSL (p>0.05). Conversely, the hardness of MBGs significantly decreased after conditioning in water and ethanol (p<0.05). Similarly, the FS values of MBCs were significantly affected after conditioning in ethanol.