The effect of the splitter plates on flow characteristics that are vertically placed to the flow between side by side cylinders in shallow water


Creative Commons License

AKAR M. A., AKILLI H., BAŞ O., Oguz B., PINAR E., ŞAHİN B.

PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, cilt.24, sa.4, ss.582-585, 2018 (ESCI) identifier

Özet

In this paper, flow changes were observed via Purticulute Image Velocimetry (PIV) technique in Shallow water flow for two side by side circular cylinders which a vertically placed splitter plate (VSP) was placed between them. The circular cylinders made of acrylic material have a diameter of D = 40 mm. Throughout the experiments water height was h(w) = 20 mm and flow images were taken ut the elevation of h(L) = 10 mm, The free stream velocity was U-infinity = 125 mm/sec and Reynolds Number was Re-D = 5000 bused on diameters of circular cylinders, Five different VSPs varied from heights of H = 2 mm to 10 mm with an increment 2 mm were used to control unsteady flow. The gap/diameter ratio was G/D = 1.25 for all cases, Dimensionless Turbulence Kinetic Energy values and time-uveruged velocity vectors were acquired by processing experimentally obtained data on a computer. Asa result, the usage of splitter plate has shown its effectiveness on flow control, After the plate height of H = 6 mm, TKE values were decreased significantly. The most effective plate height on the flow control was seen us H = 10 mm.