Performance studies of prototype II for the CASTOR forward calorimeter at the CMS experiment


Creative Commons License

Aslanoglou X., Bakirci M. N., Cerci S., Cyz A., d'Enterria D., Gladysz-Dziadus E., ...Daha Fazla

EUROPEAN PHYSICAL JOURNAL C, cilt.52, sa.2, ss.495-506, 2007 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 52 Sayı: 2
  • Basım Tarihi: 2007
  • Doi Numarası: 10.1140/epjc/s10052-007-0380-x
  • Dergi Adı: EUROPEAN PHYSICAL JOURNAL C
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.495-506
  • Çukurova Üniversitesi Adresli: Hayır

Özet

We present results of the performance of the second prototype of the CASTOR quartz-tungsten sampling calorimeter, to be installed in the very forward region of the CMS experiment at the LHC. The energy linearity and resolution, as well as the spatial resolution of the prototype to electromagnetic and hadronic showers are studied with E=20-200 GeV electrons, E=20-350 GeV pions, and E=50, 150 GeV muons from beam tests carried out at CERN/SPS in 2004. The responses of the calorimeter using two different types of photodetectors (avalanche photodiodes APDs, and photomultiplier tubes PMTs) are compared.